General Information
The Impulse Current Generator Is Used To Inspect The Capacity Of Electric Equipment Withstand Strong Impulse Current.
It Is Widely Used In Lightning Arrester And Shock Wave Anti-Interference Test Of Electric And Electronic Equipment Under Their Running Conditions And Used In Other Research Project.
This Instrument Can Generate Standard Impulse Waveforms Such As: 1/<20uS , 4<10uS, 8/20uS, 10/350uS,18/40uS And 10/1000uS. The Waveform Technical Meet The Requirement Of National Standards And IEC Standards.
Features
-
Touch screen display.
-
Current measured by rogowski coil and residual voltage measured by voltage divider or HV probe,while the wave form recorded by oscillopgraph.
-
Charging mode is constant current and discharging mode is lower spherical cylinder push triggering,phase-shift triggering or three electrodes ignition.
-
Phase-shift accuracy is up to +/- 1 degree within a range of 0-360degree,excellent in its synchronization performance and reliable in motion.
-
With functions of over-voltage ,over current detection,door open or close automatically and automatic ground.
-
PC data management with digital measurement and control system.Optical fiber isolation communication.
-
PLC control unit.
-
Suitable wave-adjustable inductance and resistor inside,which is convenient combination of various waveforms,achieving one unit serving multiple purpose.
Specifications:
-
1. Wave form is selected according to customers' requirements.
-
2000uS square wave impulse current amplitude value: 1.5KA ± 5%
-
1/<20uS gradient wave impulse current amplitude value: 20KA ± 5%
-
4/10uS impulse current amplitude value: 200KA ± 5%
-
8/20uS lightning impulse current amplitude value: 40KV ± 5%
-
30/80uS operate impulse current amplitude value: 2KV ± 5%
-
18/40uS impulse current amplitude value: 20KA ± 5%
-
10/1000uS impulse current amplitude value: 200KA ± 5%
-
2. Rated voltage: ±60KV, ±120KV
-
3. Output current: up to 200KA
More information will be provided:
GDCL-V Impulse Voltage/Current Test System 20kV/10kA